Posted in

How to check the accuracy of other equipment?

If you’re a maintenance manager, quality control supervisor, or production lead at a manufacturing, processing, or industrial facility, you already know that small inaccuracies in auxiliary equipment—those often-overlooked tools that keep core operations running—can snowball into major headaches. A misaligned conveyor belt can throw off assembly line timing by 10%, a faulty flow meter can skew batch chemical mixing by 15%, and an uncalibrated pressure gauge can lead to unsafe overpressurization in a reactor. As a supplier of other equipment (yes, the stuff that doesn’t make it into the marketing brochures but holds everything together), I’ve spent the last 12 years walking shop floors with teams that were blindsided by these exact issues. Most companies don’t have a formal process for verifying the accuracy of non-core equipment, and that’s where mistakes happen. Today, I’m breaking down the step-by-step, science-backed method our team uses with every client to make sure the tools they rely on don’t let them down. Other Equiments

First, let’s get one thing straight: when I talk about “other equipment,” I’m not referring to your CNC machines or primary production lines. I’m talking about the auxiliary gear: pallet jacks, portable test meters, flow controllers, pressure regulators, material lifts, temperature probes, and even the small calibration weights stored in a back supply closet. For decades, these items were lumped into a “set it and forget it” category, but that’s a dangerous assumption. The accuracy of auxiliary equipment directly impacts product quality, worker safety, and regulatory compliance—especially in industries like pharmaceuticals, food and beverage, and aerospace, where even a 1% error can result in rejected batches, OSHA fines, or product recalls.

The biggest mistake I see teams make is jumping straight into testing without defining what “accuracy” even means for their specific use case. A pressure gauge on a water transfer line has different accuracy requirements than one on a high-pressure gas reactor, for example. You can’t test a 0-100 PSI gauge for a low-pressure HVAC system using a 0-500 PSI test standard—that’s a waste of time and resources, and it won’t give you reliable data. Before you pick up a multimeter or a calibrator, start with two critical questions: What is the required accuracy tolerance for this piece of equipment, and how is it used in daily operations? The tolerance is usually specified by the original equipment manufacturer (OEM), but if that’s missing, look to industry standards (like ISO 9001 for general manufacturing, or ASTM for specific processes) or your company’s own quality manual. If a pallet jack is rated to safely lift 5,000 lbs, its weight sensor (if equipped) shouldn’t be off by more than 100 lbs—any more than that could lead to overloading and equipment damage or worker injury.

Once you have clear tolerance parameters, the next step is to select the right reference standard for testing. This is the foundation of accurate verification, and it’s why so many test results end up being unreliable. A reference standard is a device that is known to be accurate, with a documented calibration history that traces back to national or international standards (like the National Institute of Standards and Technology, or NIST, in the U.S.). The key here is that your reference standard must be at least four times more accurate than the equipment you’re testing. This is called the “4:1 test ratio,” and it’s a core principle in metrology, the science of measurement. If you’re testing a thermometer with an accuracy tolerance of ±0.5°C, your reference thermometer needs to be accurate to ±0.125°C or better. Using a reference that’s only slightly more accurate than the unit under test will lead to measurement uncertainty that’s too high to draw any valid conclusions. I see this all the time at client sites: a team testing a pressure gauge with a $20 analog gauge from a hardware store, when they should be using a NIST-traceable digital pressure calibrator that costs a few hundred dollars more. The hardware store gauge is calibrated to within 5% accuracy, while the industrial calibrator is accurate to 0.02%—that difference is night and day.

Next, you need to prepare the equipment and the test environment for valid results. Most people skip this step, but environmental factors alone can skew test results by 20% or more, depending on the equipment type. For example, if you’re testing a temperature probe for a refrigeration unit, test it in an environment that’s between 15°C and 25°C (room temperature) with relative humidity between 30% and 60%—extreme temperatures or humidity can throw off the probe’s readings. You also need to make sure the unit under test is in good working order before you start: no visible damage, loose connections, or worn parts. A pressure gauge with a bent needle or a leaky fitting will give you wrong readings, even if it was accurate when it left the factory. For portable equipment like material lifts, do a visual pre-test inspection: check the hydraulic hoses for cracks, the wheels for alignment, and the load-bearing forks for bending. You’d be surprised how many teams waste time calibrating a lift that has a 2-inch bend in the fork—no amount of calibration will fix that.

Now, onto the actual testing process. This will vary slightly depending on the type of equipment, but there’s a universal framework that works for almost all auxiliary gear. First, set up your test reference standard and the unit under test in a stable, level position. For a pressure gauge, connect both to a deadweight tester (the gold standard for pressure calibration) using identical fittings and hoses to eliminate pressure loss from different connections. For a flow meter, install both in a straight section of pipe (at least 10 times the pipe diameter upstream and 5 times downstream of the meter) to eliminate flow turbulence that can skew readings. Next, apply a series of known, controlled values across the unit’s full operating range. Don’t just test at one point—test at 20%, 40%, 60%, 80%, and 100% of the unit’s maximum rated capacity. This is called a “span check,” and it tells you whether the equipment is accurate at the low end, middle, and high end of its use. If you only test at 100%, you could miss that the unit is off by 10% at 20%, which is the operating point it uses most often.

For each test point, record three readings: the reference standard reading, the unit under test reading, and the actual applied value. Then, calculate the error by subtracting the reference reading from the unit under test reading. Most modern equipment will have a display that shows the reading, but for analog gauges, you’ll need to take a careful eye-level reading (no parallax error—stand directly in front of the needle, not to the side, when reading analog dials). Parallax error is a common human mistake that can add 1-2% of error to test results. For digital equipment, make sure the battery is fully charged, and wait at least 10 minutes after turning it on for the display to stabilize—cold or drained batteries can cause drift in digital readings.

After you have all your test data, it’s time to analyze it against your required tolerance. If the error is within the acceptable range, great—but don’t stop there. Record all the test data in a formal log, with dates, reference standard calibration dates, and the technician who performed the test. This documentation is critical for ISO compliance, OSHA audits, and future troubleshooting. If the error is outside the acceptable range, you have three options: calibrate the equipment, repair it, or replace it. Calibration works for many items like pressure gauges, temperature probes, and flow controllers—most can be sent back to an OEM or a certified metrology lab for adjustment to meet tolerance. If the error is extreme, or if the equipment has visible damage (like a cracked housing or worn hydraulic seals), repair might be the better option. For equipment that’s old, no longer supported by the OEM, or costs less than the cost of calibration and repair, replacement is often the most cost-effective choice. I had a client last year who kept trying to calibrate a 10-year-old material lift that cost $1,200 new—each calibration cost $300, and the lift was failing tolerance every time. We helped them source a new lift for $1,500, and it paid for itself in 18 months by eliminating downtime from overloaded or underloaded pallets.

Once you’ve completed testing and analysis, don’t forget to establish a regular maintenance and calibration schedule. The biggest mistake companies make after verifying equipment accuracy is letting it slip again. How often you need to test depends on the equipment type, how often it’s used, and its operating conditions. For equipment that’s used daily in harsh conditions (like pallet jacks in a cold, dusty warehouse), test every 6 months. For equipment that’s used infrequently (like a portable flow meter for annual process testing), test every 2 years. Always align your schedule with regulatory requirements: FDA-regulated facilities, for example, require temperature probes for food storage to be calibrated every 3 months, while aerospace components may require quarterly accuracy checks. The schedule doesn’t have to be set in stone—if you notice a unit drifting between scheduled tests, you can adjust to more frequent checks, or if a unit stays accurate for a year, you can extend the interval.

Let me walk you through a real example to make this concrete. Last quarter, I worked with a mid-sized food processing plant that was having consistent batch rejections because their inline liquid flow meters were adding 12% extra water to their cereal batter, making it too thin. The quality team had been ignoring the flow meters because they were “just auxiliary equipment,” so they hadn’t tested them in 5 years. We started by defining the requirements: the flow meters needed to be accurate to ±2%, per FDA standards for human food production. We used NIST-traceable ultrasonic flow meters as our reference standards, which had a 0.5% accuracy rating—meeting the 4:1 ratio (2% divided by 0.5% is 4, exactly). We prepared the test environment by isolating the flow meters from the main process line, so we could control the flow rate, and waited 15 minutes for the meters to stabilize at room temperature. We tested at 20%, 50%, and 100% of the meter’s rated flow: at 20%, the error was 11%, at 50% it was 10%, and at 100% it was 12%. That’s way outside the 2% tolerance. We sent the meters back to a certified metrology lab, and after calibration, their error dropped to less than 1.5% across the full range. We worked with the plant’s maintenance team to set a quarterly calibration schedule for the flow meters, and they’ve cut batch rejections by 80% since then. That’s the impact of proper accuracy testing for “other equipment” that no one was paying attention to.

If you’re still unsure about where to start, remember that you don’t have to do this alone. As a supplier of auxiliary equipment, we’ve partnered with hundreds of facilities to set up custom accuracy testing processes, source NIST-traceable reference standards, and implement scheduled calibration and maintenance plans. Whether you need help testing a single piece of equipment or overhauling your entire auxiliary equipment verification program, our team has the expertise to walk you through every step without the jargon and the hassle. Don’t let small inaccuracies turn into big problems—reach out to our team of industrial equipment specialists today to discuss your specific needs and get a tailored solution for your facility’s accuracy checks.

Telescopic Forklift REFERENCES

  1. International Organization for Standardization (ISO). ISO 9001:2015, Quality Management Systems — Requirements.
  2. United States National Institute of Standards and Technology (NIST). Handbook 133: Checking the Accuracy of Weighing and Measuring Devices for Trade.
  3. American Society for Testing and Materials (ASTM). E1259-18: Standard Practice for Calibration of Ultrasonic Flowmeters.
  4. Occupational Safety and Health Administration (OSHA). 29 CFR 1910.178: Powered Industrial Trucks.
  5. International Bureau of Weights and Measures (BIPM). Guide to the Expression of Uncertainty in Measurement (GUM).